Roller Shutters
Series 130 Steel


Series 130 Steel Roller Shutters provide high strength security and are easy to operate. They are used for commercial and industrial applications such as loading docks, workshops, warehouses, car parks and storage buildings. The individual interlocking slats enable economical repair if the curtain becomes damaged. Wind locks are available for extra protection against strong winds.

Features
 Vision/Ventilation Roller Shutter
 Interlocking steel slats


Series 130 Shutter

Door Dimensions
Maximum Height: 6500mm
Maximum Width: 10000mm
NOTE: Maximum door dimensions may vary depending on wind loading and the door’s design features and application, it is recommended you consult your Airport Doors representative for further information.

Curtain
The Series 130 curtain shall be constructed from individual roll-formed, interlocking steel slats of 130mm profile. The interlocking slats shall be manufactured from galvanised steel sections of 0.6mm, 0.8mm of 1.0 mm thick as standard. Thickness of steel is determined per application depending on door width and wind loading. Slats are fitted with nylon end clips to stop lateral movement of the curtain and ensure smooth operation.
Wind lock clips: shall be fabricated from mild steel, formed to suit specially designed guide channels and can be riveted to every second or fourth slat as required or specified. Wind locks provide extra protection against strong winds and are optional except in cyclonic areas, and are recommended for shutters over 6m width. When specified, deflection of Roller Shutter can be reduced by installing the door as high as practicable.

Finish
The curtain shall be fabricated from galvanised material as standard and can be powdercoated (up to 8000mm width) when specified.

Ventilation (Optional)
Ventilation to the Roller Shutter curtain can be provided by either slotted slats or vision air (perforated) slats.
Slotted slats - 126mm wide by 30mm high at 150mm intervals. An airflow of approximately 9% per slat is achieved. Intervals may be shortened, upon request, to allow airflow of up to approximately 12% per slat.
Visionair slats - consist of 1.0mm thick galvanised perforated material with 2mm perforations.

Personal Entry and Exit Doors (Optional)
Personal entry and exit doors for personal access are available for applications where the shutter is the only entrance into the building. They are only recommended for small to medium width Roller Shutters over 2700mm in height that are not exposed to high wind loading. The door may be opened inwards as standard or outwards where specified. Personal entry and exit doors are fitted with a standard lock using Lockwood 201 night latch. Other locks may be available where specified.
Standard entry doors open inside and are of 1000mm high by 600mm wide fitted approximately 300mm above floor level.
Standard exit doors are opened outward and are 2040mm high by 1000mm wide fitted approximately 50mm above floor level.

Bottom Rail
For small to medium sized doors the bottom rail shall be manufactured from specially extruded, heavy duty aluminium section which interlocks to the bottom slat. Doors over 6.3m in width shall consist of a steel box section which interlocks to the bottom slat.

Locking
Hand operated steel Roller Shutters shall Padlocks not supplied by Airport Doors.
Steel Roller Shutters shall be fitted with a steel chain lock or alternatively can be fitted with two shootbolts, fitted internally to either end of the bottom rail. Padlocks not supplied by Airport Doors. Motorised steel Roller Shutters shall be fitted with a push button station internally as standard. Key switch is optional and can also be fitted externally.

Centre Mullions (Optional)
Centre door mullions can be used for wide openings and/in multiple door installations. Centre door mullions shall be manufactured from mild steel plate having a standard width of 250mm. The mullions shall be supplied either being of a sliding or fixed type (as selected). The sliding mullion is manually operated by disengaging top and bottom levels and sliding to one side of the doorway opening on an overhead sliding door track, fixed to the underside of the door head lintel. The fixed type mullion is not removable and is fixed to the floor and lintel.

Operation
Roller Shutters operate by means of a flexible curtain guided in steel tracks and revolving on a roller drum. See Method of Operation.

Chain Operation
Gearing shall be fitted to one end of the Roller Shutter and matched to suit door size and weight. Chain operation is not recommended over 20m².

Motorisation
See Industrial Operators.


PDF DOWNLOADS

Series 130 Steel Roller Shutter (.pdf format, get Adobe Acrobat Reader)

Technical Datasheet RS2 - Personal Access Door (.pdf format, get Adobe Acrobat Reader)

Technical Datasheet RS3 - Motorisation Options (.pdf format, get Adobe Acrobat Reader)

Series 100 Steel Roller Shutter (.pdf format, get Adobe Acrobat Reader)



Top